Research Library · Idea
32 CFR 117.15
32 CFR 117.15, Safeguarding classified information, is the section of the National Industrial Security Program Operating Manual (NISPOM), 32 CFR Part 117, that tells cleared contractors how to protect classified information in their custody. Part 117 sits in the Department of Defense subtitle of Title 32; its source is 85 FR 83312 of 21 December 2020, and its listed authorities include Executive Orders 12829 and 13526. 1 The eCFR text of the section, up to date as of 24 November 2026, matches the official edition revised as of 1 July 2025. 12
Paragraph (a) makes contractors responsible for safeguarding classified information in their custody, with storage approved by the cognizant security agency (CSA), and requires end-of-day security checks, perimeter controls and emergency procedures. Paragraph (b) points contractors to 32 CFR Part 2001 when buying storage and destruction equipment and requires repairs to GSA-approved containers and vaults to follow Federal Standard 809. Paragraph (c) limits storage to GSA-approved security containers, vaults built to Federal Standard 832 and open storage areas built under 32 CFR 2001.53, and applies the storage rules of 32 CFR 2001.43 for each classification level. 23
Paragraph (d) sets minimum standards for intrusion detection systems used as supplemental protection for Top Secret and Secret. The CSA must approve a system before it is installed, basing approval on Intelligence Community Directive 705, UL 2050 or its own written standards. Installers must be certified by a nationally recognised testing laboratory (NRTL), and equipment not tested and approved by an NRTL needs CSA approval. The system must be switched on at close of business whenever cleared staff are not in the area, alarm records are kept for 12 months, and responses must meet the time limits in 80 percent of cases; where traffic or distance genuinely prevents the Top Secret limit, the CSA may allow up to 30 minutes. Coverage must include all probable points of entry and intruder paths, and, citing Federal Standard 809, the section bars alarm sensors such as magnetic contacts or vibration detectors on GSA-approved containers. 2
Paragraph (e) covers information controls, including extra accountability for Top Secret material. It requires combinations to vaults, open storage areas and containers to be protected at the level of the most sensitive information they guard, with changes following 32 CFR 2001.43(c) and 2001.45(a)(1). 2
Source · 32 CFR 117.15 -- Safeguarding classified information (opens in a new tab) · Office of the Federal Register, eCFR
References
- 32 CFR 117.15 -- Safeguarding classified information (opens in a new tab) · Office of the Federal Register, eCFR · Current text with Part 117 authority and source notes; up to date as of 24 November 2026. ↩ ↩
- 32 CFR 117.15, Safeguarding classified information (opens in a new tab) · U.S. Government Publishing Office (GovInfo) · July 1, 2025 · Official annual edition, revised as of 1 July 2025. ↩ ↩ ↩ ↩
- 32 CFR 2001.43, Storage (opens in a new tab) · U.S. Government Publishing Office (GovInfo) · July 1, 2025 · Code of Federal Regulations, annual edition revised as of 1 July 2025. ↩
Research articles
- Detect, assess, respond: intrusion alarms, monitoring stations and what a UL certificate promises · Physical security
- Building a SCIF: what ICD 705 and the IC Tech Spec require, and what is only reported about changes in 2025 and 2026 · Physical security
- Safes, vaults and GSA containers: what UL 687, UL 768 and FF-L-2740B ratings promise, and how classified storage is specified · Physical security
See what connects to it on the map of ideas →