Abstract

What does an intrusion alarm system with a UL certificate actually guarantee? For stopping an intruder, an alarm counts only if a credible response arrives before the intruder finishes. Sandia’s physical protection methodology states this as the principle of timely detection: the response timeline, which runs through alarm communication, assessment and deployment, must be shorter than the adversary’s remaining task time. UL alarm service certificates for installations made to UL 681, the UL 827 monitoring-station listing and UL 2050 certification cover parts of that chain: listed components, an installation of a stated extent, a monitoring station that meets building, staffing and signal-handling rules, and an alarm company audited by UL. They do not certify that the response beats the adversary. For classified storage, 32 CFR 2001.43 sets arrival times of 15, 30 or five minutes after alarm annunciation, and for cleared contractors 32 CFR 117.15 sets a response standard of “80 percent within the time limits”. Nuisance alarms, police verification policies and documented flaws in communicators, panels and monitoring software all erode the margin. The decision this supports: accept an alarm design only after measuring its timeline against a stated threat and testing the path end to end.

The alarm is one event in a race

An intrusion detection system (IDS) does nothing physical to an intruder. It turns an intrusion into a signal and relies on people to interpret it and act. Mary Lynn Garcia of Sandia National Laboratories names the three functions of a physical protection system as detection, delay and response: there must be awareness that an attack is under way, slowing of the adversary’s progress, and responders with enough time “to interrupt or stop the adversary from completing the attack”.1 Two consequences follow for the goal of interrupting an attack.

The first is that, for interruption, delay only counts after detection. Garcia writes that delay before detection “is of no value to the effectiveness of the security system because it does not provide additional time to respond to the adversary”, and that it “is primarily a deterrent.”1 In that model, a heavy door that an intruder cuts through before any sensor notices adds nothing to the probability of interruption, whatever it contributes as deterrence.

The second is that detection has to happen early enough. Sandia’s training material for evaluating physical protection systems defines the principle of timely detection: the system “must detect the adversary early enough along the adversary timeline that the response force has enough time along its timeline to be able to interrupt the adversary before theft or sabotage is completed.” The last detection opportunity on a path at which the response force can still win is the critical detection point. “Without timely detection the PPS is ineffective.”2 The same material spells out what the response timeline contains: “times for detection, alarm communication, assessment, communication to the response force, and response force deployment.”2 Designing out crime treats layered perimeters and timely detection as a design problem.

Sandia also breaks detection into factors: the probability that the sensor senses the intruder, that the alarm is transmitted, and that it is assessed correctly, combined “based on the basic laws of probability” so that “probability of detection PD = PS PT PA”.2 Read as a chain without assuming independence, each factor is conditional on all the preceding steps having succeeded. A well-rated sensor on a path that can be disrupted, watched by an operator who discounts that zone, has a low product. The same chapter says the system can take credit for delay only after assessment: “just because a sensor activates does not necessarily mean that the system can take credit” for the delay; it counts “only upon successful assessment and activation of the response function”.2

Both timelines are made of segments:

Adversary timelineDefender timeline
Approach and breach outer barriers, often before any sensorSensor activation (if the sensor senses at all)
Breach of the alarmed perimeter or roomSignal reaches the panel, then the monitoring station
Travel to the targetAlarm annunciated; operator assesses (video, other zones, a call); delay credit starts only once assessment succeeds and the response is activated
Defeat the container or other delay at the targetDispatch; responders travel, arrive and deploy where they can intervene
Remove or damage the asset; leaveResponders interrupt, then neutralise or contain

A certificate, a sensor listing or a regulation addresses one or two cells in the right-hand column. Whether that column finishes first depends on the whole installation, the response arrangements and the adversary assumed, the subject of How a facility’s security is decided.

Sensor families and what each one actually senses

The Department of Defense design criteria UFC 4-021-02, Electronic Security Systems (28 July 2025), describe an IDS as “sensors connected via intrusion panels and a network to a central system consisting of a file server and an alarm monitoring workstation”. They name four performance metrics: “probability of detection, nuisance alarm rate (NAR), false alarm rate (FAR), and vulnerability to defeat.”3 The fourth gets no public treatment: “No additional discussion of vulnerability to defeat is provided in this document due to concerns over security classification.”3 Defeat modes below are limited to those public sources describe.

Point sensors on doors and openings: magnetic contacts and balanced magnetic switches

The 1986 Navy design manual called the door switch “the most commonly used intrusion detection device”.4 A magnet on the door holds a reed switch on the frame in its normal state until the door opens. The manual, Commercial Intrusion Detection Systems (DM-13.02, September 1986), notes that a plain magnetic switch is susceptible to an external magnet, and for that reason “the only acceptable type of magnetic switch for most DoD applications is the balanced (or biased) magnetic switch (BMS).”5 UFC 4-021-02NF replaced the manual in 2006.6

The manual describes biased, balanced and preadjusted balanced switches, which add reeds and biasing magnets to resist magnetic interference, and it says that even these remain vulnerable to an expert.5 It warns, of point sensors generally, that they “can be bypassed by a skillful and knowledgeable intruder”.4

Today the relevant product standard is UL 634, Connectors and Switches for Use with Burglar-Alarm Systems (ninth edition, 12 October 2007, last revised 24 September 2025), whose scope covers switches “to supervise doors, windows, hatches, vents, trap doors, and the like”.7 Its high-security switches come in Level 1 and Level 2. Intertek’s summary of a 2015 revision shows compromise tests that apply to both levels (section 54) and additional foreign magnetic field tamper and compromise tests for Level 2 only (sections 63 and 64).8 For defensive selection, the practical point is that Level 2 has been tested against more forms of magnetic interference. UFC 4-021-02 requires UL 634 Level 2 high-security switches for SCIFs and SAPFs, saying they “meet additional requirements for performance, tampering, nuisance alarms, and reliability”, prefers recessed models, and requires the tamper circuit to be connected and kept in “continually monitored mode”.3 The intelligence community’s technical specification for SCIFs requires “UL 634 listed High Security Switches (HSS) that meet UL Level II requirements” for new accreditations and a test that the switch alarms “before the non-hinged side of the door opens beyond the thickness of the door”.9 The US Nuclear Regulatory Commission lists “Door mounted balanced magnetic switches” among interior systems at licensed facilities.10

Interior volumetric sensors: PIR, microwave and dual technology

A volumetric (motion) sensor watches a volume. UFC 4-021-02 explains the two common principles: passive infrared (PIR) detection “is based on infrared (IR) energy (heat) changes within the coverage pattern, while microwave detection is based on a moving object shifting the frequency of the microwave energy.”3 Their directional sensitivity differs: a PIR sensor “is most sensitive to motion perpendicular to its aim point direction”; a microwave sensor “is most sensitive to motion directly toward and away from the sensor.”3 Coverage design has to account for both.

Nuisance causes are specific. Microwave sensors “can penetrate through walls” and are “susceptible to nuisance alarms by movement outside of the protected area”, and are prone to alarms from “fan blades and small animals”; PIR sensors are “prone to nuisance alarms caused by heat sources (space heaters and windows)”, and in unconditioned spaces their probability of detection “may be reduced as the ambient temperature approaches the temperature of the human body.”3 The 1986 Navy manual adds that fluorescent lighting “can appear as a moving target” to microwave sensors and that wind moving a large metal overhead door “as little as 0.25 inch” can cause nuisance alarms.11

Dual-technology sensors combine PIR and microwave in one housing. Most are factory set to “and” logic, requiring both to trip. UFC 4-021-02 states the trade: “the benefit of ‘and’ logic is the potential to reduce the NAR”, while “or” offers “the potential for higher probability of detection”; with “and” logic, an intruder who avoids either technology stays silent. It says that in “certain high-security areas such as SCIFs, the ‘or’ logic configuration must be used”, subject to the applicable security policy, and gives a coverage goal: “detect an intruder within four steps of entering the secure space.”3 The SCIF technical specification allows dual-technology sensors only “when each technology transmits alarm conditions independent of the other technology”, and defines the acceptance test: an alarm on at least three of four consecutive trials, each trial four steps at about one step per second.9

Vibration, seismic and glass-break sensors

Vibration sensors detect attack on a rigid barrier; UFC 4-021-02 notes that “plywood and drywall are not well suited for the use of vibration sensors” and warns of nuisance alarms from machinery, rail traffic and blasting ranges. Glass-break sensors either sense shock in the pane or listen for breaking glass, and acoustic types are “not recommended for noisy environments”.3 UL 639, Intrusion-Detection Units (eighth edition, 2007, revised 18 June 2024), is the listing standard for such detectors.12

Capacitance sensors for objects

A capacitance proximity sensor turns an insulated metal object, from a safe or file cabinet to a vehicle, into the sensing element, and alarms when someone touching the object disturbs its capacitance to ground.13 In classified storage, 117.15 says that “in accordance with Federal Standard 809, no IDS sensors (magnetic contacts or vibration detectors) will be installed on GSA-approved security containers”, so detection is of the room or area and the container contributes delay.14

Perimeter sensors

Perimeter sensors work outdoors, and weather and wildlife recur throughout UFC 4-021-02’s nuisance-alarm guidance for them.3 The NRC distinguishes volumetric systems, which “detect disturbances of a volume of space”, from planar systems, “such as fence disturbance and infrared systems”. A volumetric field “must be sufficiently high and wide to prevent jumping across without detection” and “sufficiently low to detect someone attempting to crawl beneath it.”10

UFC 4-021-02 gives design limits for each family, summarised in the table below; fence-disturbance performance, for example, “is highly dependent on proper fence construction”.3

Summary of sensor families

FamilyWhat it sensesTypical nuisance causesDocumented limits and defeat modes
Plain magnetic contactSeparation of a magnet from a reed switchNot addressed in the cited criteriaSusceptible to magnetic interference; not acceptable for most DoD uses in the 1986 manual5
Balanced magnetic switch / UL 634 HSSSame, with extra reeds and tamper circuitsOn perimeter gates, gate movement in wind3Needs properly aligned doors before installation; older designs still vulnerable to an expert; Level 2 adds foreign-field tests358
PIRChange in infrared (heat) in its patternSpace heaters, windows3Most sensitive to motion across its aim; weaker as ambient temperature nears body temperature3
MicrowaveDoppler shift from moving objectsFans, small animals, movement beyond walls, fluorescent lights311Most sensitive to motion toward or away from it; penetrates walls3
Dual technologyBoth, in “and” or “or” logicPotentially fewer with “and” logic3With “and” logic both must trip; UFC requires “or” in certain high-security areas such as SCIFs; the SCIF specification requires each technology to alarm independently39
Vibration / seismicEnergy from attack on a rigid barrierMachinery, rail traffic, blasting3Poor on plywood and drywall; depends on attachment3
Glass-breakShock in the pane or the sound of breaking glassNoise in the room3Range cut by curtains; rated for specific glass types3
CapacitanceChange in capacitance of an insulated metal objectRelatively insensitive to environmental factors that affect volumetric sensors13Object must be isolated; not permitted on GSA containers for classified storage1314
Fence-disturbanceVibration of fence fabricWind, wind-blown rain and debris, animals3Depends on fence tension and construction3
Bistatic microwaveDisturbance of a field between two headsStanding water or runoff, wildlife3Path must be kept clear of vegetation and snow; gaps over uneven ground and near the heads for crawlers3
Active infrared beamsInterruption of beams between towersHeavy rain, fog, snow, wildlife3Needs clear, level ground between towers3

How quiet a sensor must be

Public design documents set numerical targets, each with its own definition and averaging period. UFC 4-021-02 requires “a probability of detection of at least 95%, with a goal of 99%”, applying to intrusion attempts “within the sensor’s intended coverage area”. It distinguishes a nuisance alarm, “caused by a clearly identifiable stimulus that does not represent an intentional intrusion attempt”, from a false alarm, “an alarm for which no cause can be determined”. For interior sensors, NAR “must not exceed three alarms per month” and FAR “one alarm per month”, as averages over a 12-month evaluation period; for exterior perimeter sensors the limits are three and one per day, and for wide-area sensors 15 and three per day, both averaged over 30 days.3 The SCIF specification sets a different measure: “False alarms shall not exceed one alarm per 30-day period per IDS partition”, where a false alarm is any alarm “transmitted in the absence of a confirmed intrusion that is caused by changes in the environment, equipment malfunction or electrical disturbances”, so it counts what UFC would split into nuisance and false alarms.9 The two figures are not directly comparable.

From premises to monitoring station: line security and supervision

A sensor’s output travels to the panel and from the panel to whoever is watching; on each segment an alarm can be lost, delayed or forged.

Supervision

UFC 4-021-02 requires “end-to-end supervision of the entire system”: any disruption to the sensor-to-panel, panel-to-server and server-to-workstation links “must be immediately annunciated”. For the sensor-to-panel connection, it says DC line supervision with an end-of-line resistor inside the sensor housing is typical; panel-to-server and server-to-workstation connections typically use poll-and-response supervision over the network. The document adds that “encryption of IDS data connections is not a universal requirement”.3 Its chapter on data transmission states the rule for supervised field circuits: an alarm on “opening, closing, shorting, or grounding of the signal”, and for data transmission media, an alarm “upon any manipulation or disruption of the signal.”3 The 117.15 wording is shorter: line security means “the connecting lines are electronically supervised to detect evidence of tampering or malfunction.”14

Line security classes

UL classifies the premises-to-station link by construction of the equipment. The scope of UL 1610, Central-Station Burglar-Alarm Units, says such systems “may be classified as either standard line security equipment or encrypted line security equipment”; UL 1076, Proprietary Burglar Alarm Units and Systems, uses the same two classes.1516 Both standards are now marked superseded. UL 2610, Commercial Premises Security Alarm Units and Systems (second edition, 7 April 2021, reaffirmed 17 December 2025), replaced them along with UL 365, UL 603, UL 609, UL 636 and UL 1635 (digital alarm communicators).17 The SCIF specification (version 1.5.1, 26 July 2021) still refers to UL 1610 and UL 1076. It treats three links separately. IDS transmission lines from the SCIF to the monitoring station must meet FIPS requirements for certified encrypted lines, with the standard “noted on the UL 2050/CRZH Certificate”; it names FIPS 197 or FIPS 140-2 for control units certified under UL 1610 and FIPS 140-2 for those under UL 1076, and alternative methods “shall be approved by the AO and noted on the IDS Certificate”. IDE cabling that extends beyond the SCIF perimeter must use encrypted line security or a closed and sealed ferrous conduit (section A.2.e); separately, sensor-to-PCU cabling that cannot be contained within the SCIF must meet the external transmission line security requirements of section A.3.b(10), including its FIPS and AO-approval provisions. For an IDS on a LAN or WAN, transmissions must be encrypted using FIPS 140-2, a VPN or sealed conveyance, with FIPS 197 (AES) allowed with AO approval.9 Those FIPS references are the 2021 document’s; NIST’s validation programme moved FIPS 140-2 validations off its active list on 22 September 2026, leaving only FIPS 140-3, so current acceptance of a particular encryption method rests with the AO.18

The supervision intervals, meaning how long a path may be silent before a trouble signal must be raised, are set in the paid UL standards, and their public summaries do not state them. Two public provisions give related figures with different triggers. The SCIF specification allows a secondary communication path “to reduce investigations of data communication failures of less than five minute duration”, with supervision equivalent to the primary and wireless only with approval.9 Separately, a UL certification requirement decision on edition 5 of UL 2050 required that if a monitoring automation system cannot process signals “beyond the 90 seconds resumption time”, the connected receivers revert to displaying and recording signals themselves.19

What happens when supervision fails

Two different rules apply, one operational and one about installation. The SCIF specification deals with a failed system: if any IDS component is disrupted so that the system no longer provides essential monitoring, for example through “loss of line security”, then “SCI-indoctrinated personnel shall physically occupy the SCIF until the system is returned to normal operation”, or the outside perimeter is continuously monitored by a response or guard force; IDS failure “shall be addressed in the SCIF emergency plan”, and repairs must start “within 4 hours of the receipt of a trouble signal”.9 Section 117.15(d)(4) deals with design: where line security is not available, the installation needs CSA authorisation on the alarm system description form and “two independent means of transmission of the alarm signal from the alarmed area to the monitoring station”, and alarm transmission over data networks needs CSA acceptance criteria such as encryption.14 Both depend on a loss of service being noticed. A forged or suppressed message on a working path is a different failure, and line supervision is designed to detect tampering or malfunction of the line.

UL’s certificate system

UL lists insurance companies and regulators among the stakeholders who rely on its alarm certificate, and 32 CFR 117.15 uses NRTL certification as evidence of compliance for cleared contractors, so its scope matters.2014

Who issues what

UL Solutions’ description of its security alarm service certification names UL 681, Installation and Classification of Burglar and Holdup Alarm Systems, and UL 827, Central-Station Alarm Services, as the applicable standards. It calls the UL Certificate the alarm service company’s evidence that equipment, installation, maintenance and service meet “the minimum standard requirements”. Only a UL Listed alarm company can issue one, and the company keeps its listing by passing an annual UL audit. A monitoring station listed only as a residential monitoring station cannot issue a certificate itself; a certificate needs a contract with a listed alarm service company.20

UL 681 (fifteenth edition, published 16 January 2014, last revised and ANSI approved 25 September 2025) covers “the installation of protective wiring and devices for burglar alarm systems covering premises, stockrooms, alarmed areas, safes, vaults, night depositories, automated teller machines, and other security containers.” It classifies systems by type (central station, mercantile, bank, proprietary and national industrial security) and says that “the amount of alarm protection installed in a system is designated as the extent of protection.”21 It sends each type of system to the right kind of monitoring: a national industrial security system transmits to a government-contractor monitoring station complying with UL 2050, a central station complying with UL 827, or “the dispatch location of the law enforcement agency having jurisdiction”.21

UL 827 (ninth edition, 8 November 2022, last revised 24 August 2026) covers central stations, residential monitoring stations, “redundant sites”, “remote signal management centers” and “hosted central-station service providers”, with “trained operators on duty at all times.”22 UL Solutions summarises its requirements as “building, equipment, standby power, communication infrastructure, physical security, staffing, signal processing, signal retransmission and record-keeping.”20 The August 2026 revision added requirements titled “Operator Connectivity Supervision”.22

UL 2050, National Industrial Security Systems, was “developed in collaboration with U.S. federal security agencies” and describes “the elements of alarm protection (intrusion detection) needed to coordinate with related security measures that come into force when defense contractors hold sensitive material.” UL lists two categories: national industrial security systems (CRZH) and national industrial monitoring stations (CRZM); the systems are monitored for openings, closings, and alarm and trouble signals.23 The current sixth edition was published on 7 April 2025; the fifth was dated 5 November 2010.2419

UL 1981, Central-Station Automation Systems (third edition, 29 October 2014, revised 29 March 2023), covers the software side: “automation system units and accessories intended to be used in central-stations and proprietary stations for the reception, processing, dispatch, responses, and record keeping” of signals, including “LAN/WAN network communications”. It excludes the building, staffing, power and spare parts, which stay in UL 827.25

What the certificate obliges, and what it leaves open

The certificate is issued by a listed alarm service company, and the listing commits that company to UL’s annual audit.20 For mercantile service, UL says the standards leave the response to the contract: “Specific responses to alarm signals are not defined in ANSI/UL Standards”; the response is agreed between provider and subscriber “and is noted in the service agreement.”20 For central-station service, UL says “runners are on duty at all times and are dispatched to investigate any unauthorized entry”, and “local law enforcement may also be dispatched”.20 UL’s public page does not give a runner arrival time.

UL notes, for example, that “an insurance company may require that the security alarm system be equipped with line security.”20 For cleared contractors, 117.15 makes “a valid (current) certification by an approved NRTL for the appropriate category of service” the evidence of compliance. The certificate is issued “by the NRTL, through the alarm service company”, and shows that the installing company is listed, authorised to issue it, and “subject to the NRTL inspection program whereby periodic inspections are made of representative alarm installations”.14 The laboratory inspects a sample of installations, which is a check on the company’s certification practice.

Certificate or listingCoversWho issues itWhat it obliges
UL alarm service certificate, installation to UL 681 (central-station, mercantile, bank, proprietary or national industrial type)Installation, wiring and extent of protection at the premisesA UL Listed alarm service company, under annual UL auditInstallation, maintenance and service to the standards; for mercantile service, response as agreed in the service agreement2120
UL 827 monitoring-station listing (central station or residential monitoring station)The monitoring facility: building, power, communications, staffing, signal handling, recordsUL lists the station; a station alone cannot issue a certificateTrained operators on duty at all times; runners for central-station service2220
UL 2050 national industrial security system certificate (CRZH), for the protected facilityThe installed system at a cleared contractor holding classified materialThe NRTL, through a listed alarm service companyMonitoring of openings, closings, alarm and trouble signals; under 117.15 a CSA-approved extension of the Top Secret response time goes on the alarm system description form and is noted on the alarm certificate; the SCIF specification requires the FIPS standard to be noted on the UL 2050/CRZH certificate23149
UL 2050 national industrial monitoring station listing (CRZM)The station that receives national industrial security signalsListing by ULTrained personnel to handle and record signals and notify responders23
UL 1981 automation systemMonitoring software and its networkingProduct listing of the softwareDesign and support of the automation software; installation rules sit in UL 82725
UL 634, UL 639 and UL 2610 product listingsSwitches, detectors, control units and communicatorsProduct certification by a testing laboratoryConstruction and performance of the device as tested71217

Federal rules that tie response time to storage

For classified storage, public rules write the response time down.

32 CFR 2001.43

The Information Security Oversight Office (ISOO) directive at 32 CFR 2001.43 requires classified information to be stored “only under conditions designed to deter and detect unauthorized access”. For Top Secret held in a GSA-approved container, one supplemental control is required: inspection “every two hours by an employee cleared at least to the Secret level”; or “an Intrusion Detection System (IDS) with the personnel responding to the alarm arriving within 15 minutes of the alarm annunciation”; or security-in-depth coverage of the area, “provided the container is equipped with a lock meeting Federal Specification FF-L-2740.” For Top Secret in open storage covered by security-in-depth, the IDS response is 15 minutes; for open storage “not covered by Security-In-Depth, personnel responding to the alarm shall arrive within five minutes of the alarm annunciation.”26

Secret may be stored in the same ways as Top Secret; an alternative allowing non-GSA-approved containers ran only “until October 1, 2012”. Secret in a GSA-approved container or a vault built to FED STD 832 needs no supplemental control. Secret in open storage needs security-in-depth and either inspection “every four hours” or “an IDS with the personnel responding to the alarm arriving within 30 minutes of the alarm annunciation.” Confidential information needs no supplemental controls.26 The definitions section describes security-in-depth as “a determination by the agency head that a facility’s security program consists of layered and complementary security controls sufficient to deter and detect unauthorized entry and movement within the facility”, with examples that include fences, access controls, an IDS, random guard patrols and video, and lists IDS, periodic inspections and security-in-depth as examples of supplemental controls.27

Three features of the rule deserve attention.

First, the interval runs from “alarm annunciation” to the responders “arriving”. Whatever happens after annunciation, including the operator’s assessment and the dispatch call, uses up part of the 15, 30 or five minutes. What happens before annunciation, the intruder’s approach, the sensor tripping and the signal’s transit to the station, is outside the interval, so the specifier has to add those segments to compare the rule with Sandia’s full response timeline.262 The rule does not define annunciation as a particular console event. For contractors, 117.15 requires records of the “time of receipt of alarm”, the dispatch time and the arrival time, and receipt as logged may not coincide with the moment the alarm was annunciated to an operator.14

Second, the trade is between kinds of control, and the regulation does not link the response time to the delay of the container. GSA lists both Class 5 and Class 6 containers as “GSA-approved for Secret, Top Secret, and Confidential information”, with 10 man-minutes of forced-entry protection for Class 5 and “No forced entry requirements” for Class 6.28 The underlying GSA federal specification for security filing cabinets, AA-F-358K, rates a Class 5 cabinet at “10 man-minutes forced entry” and says of Class 6 cabinets: “No forced entry requirements.”29 Man-minutes there are working time under a defined qualification test: testers may study the design beforehand, at most two work at once, tools are limited by type, volume and weight, and the clock excludes “time required for safety precautions and rest periods.”29 They are a minimum test result, not an elapsed-time estimate for a particular threat. The 15-minute IDS option in 2001.43 is written for GSA-approved containers without reference to class. Class 5 and 6 cabinets also carry surreptitious- and covert-entry ratings that matter against a quiet adversary; against a forced attack, any delay the cabinet does not provide has to come from detection and response.

Third, Top Secret open storage without security-in-depth requires arrival within five minutes, against 15 minutes when security-in-depth covers the area.26 The rule pairs fewer layered controls with a shorter required arrival time.

32 CFR 117.15 and the cleared contractor

The NISPOM rule for contractors applies the 2001.43 storage rules in 32 CFR 117.15(c) and sets “the minimum standards for an approved IDS” in 117.15(d). CSA approval is required before installation, based on ICD 705, UL 2050 or the CSA’s own written standards. Installation is by an alarm services company certified by an NRTL, or by an entity the CSA approves in writing, and intrusion detection equipment is to be “tested and approved (or listed) by a NRTL, ensuring its proper operation and resistance from tampering”; equipment without NRTL approval needs CSA approval.14

The rule then deals with people. Monitoring may be by a government contractor monitoring station or a cleared commercial, protective signal service, residential or national industrial monitoring station; Secret-cleared operators must be “in attendance in sufficient number to monitor each alarmed area”, and records must be kept for 12 months of the time each alarm was received, who responded, when they were dispatched and arrived, the nature of the alarm and the follow-up.14 The IDS “must be activated at the close of business whenever the area is not occupied by cleared personnel”, and, as a separate condition, any exit delay “must expire prior to the cleared personnel leaving the immediate area.”14

Its response provisions are where the arithmetic gets loose:

  • Response times follow 2001.43, but “when environmental factors (e.g., traffic, distance) legitimately prevent meeting the requirements for TOP SECRET information ... the CSA may authorize up to a 30-minute response time”, documented on the alarm system description form and “noted on the alarm certificate.”14
  • “The requirement for response is 80 percent within the time limits.”14
  • The first responders may be uncleared. If an alarm “resets in a reasonable amount of time and no damage to the area is visible, then entrance into the area is not required and an initial response team may consist of uncleared personnel.” If the alarm does not reset and damage is observed, a cleared team must be dispatched, and the initial uncleared team “must stay on station until relieved by the cleared response team”; if the cleared team does not arrive within an hour, a report must be made to the CSA by the close of the next business day. Uncleared guards from a commercial station stay “until a designated, cleared representative of the facility arrives, or for a period of not less than 1 hour, whichever comes first”; if the representative has not arrived within an hour of the guard, the central station reports the incident to the CSA by the end of the next business day.14
  • Where police are the primary response, CSA authorisation on the alarm system description form is required, and “the contractor must obtain written assurance from the police department regarding the ability to respond to alarms in the required response time.”14

The mission given to responders is to “ascertain if intrusion has occurred and, if possible, assist in the apprehension of the individuals involved.”14 In Sandia’s terms, the regulation specifies arrival, which bears on the probability of interruption; it says little about the probability of neutralisation, which Sandia defines as the probability that the response force “will gain complete physical control of the adversary force” once it has interrupted.2 Where an alarm resets and no damage is visible, an uncleared initial response that arrives in time and does not enter can satisfy the initial-response provision.

The SCIF specification

The intelligence community’s Technical Specifications for Construction and Management of Sensitive Compartmented Information Facilities, version 1.5.1 of 26 July 2021, applies the same response times to fixed SCIFs within the U.S. (chapter 3): a closed-storage “response time of 15 minutes”, and open storage “within 15 minutes of the alarm annunciation if the area is covered by SID or a five minute alarm response time if it is not.”9 It describes security-in-depth as “the factors that enhance the probability of detection before actual penetration to the SCIF occurs”, which with approval may “extend security alarm response time to the maximum of 15 minutes.”9 It requires IDS components and monitoring stations to comply with UL 2050 and an “Extent 3 installation”, disables auto-reset, requires failed sensors to cause “immediate and continuous alarm activation”, limits entry delay to 30 seconds and requires 24 hours of backup power and semi-annual testing. Separately from the initial response force, which safeguards the SCIF under a written support agreement, an SCI-indoctrinated person must arrive “in accordance with UL 2050 requirements (60 minutes) or the response time approved by the AO, after receipt of the alarm signal” to inspect the SCIF and reset the system.9 It is a fuller system specification than a commercial certificate, and it still measures arrival.

The monitoring station as a networked computer

The monitoring station is a computer system. Premises equipment can report to it over IP under SIA DC-09, and the systems in the Michigan State study reported over cellular networks.3031

Protocols and paths

The SIA standard DC-09, Internet Protocol Event Reporting, “details the protocol and related details to report events from premises equipment to a central station using internet protocol (IP)”, for event transport “possibly using the public internet”; compliance “is voluntary”.30 In the older edition reproduced online (text marked © 2007 to 2020), examples carry events in SIA DC-04 format and in the Contact ID format standardised as DC-05, and the encryption clause reads: “Encryption support is optional for PE. Encryption support is mandatory for CSRs”, where PE is premises equipment and CSR the central-station receiver; encrypted messages use AES per FIPS 197.32 The Security Industry Association announced DC-09-2026 on 3 March 2026, adding “encryption key rotation for stronger long-term cybersecurity”, “autocommissioning capabilities” and “continued backward compatibility, preserving support for legacy formats.”33 SIA’s public summaries of the 2026 edition do not say whether encryption support remains optional for premises equipment.3033

UFC 4-021-02 is cautious about radio: “only use wireless if other media cannot be used”, because “one disadvantage of wireless systems is the systems are susceptible to jamming”.3

Documented vulnerabilities

Some cases with primary documentation:

  • CSL DualCom CS2300-R (United Kingdom, 2015). CERT/CC vulnerability note VU#428280, published 23 November 2015, reports a researcher’s findings that GPRS alarm signalling boards protected messages to alarm receiving centres with a proprietary substitution cipher, hardcoded keys and no message authentication, so that a capable attacker “may be able to bilaterally spoof or block any messages between endpoints”, producing “false alarms, suppressed alarms”. The vendor disputed the findings, stating that the product “has been certified as compliant to the required European standard EN-50136” and that its “internal review of the report concluded there is no threat to these systems”.34 The disagreement is between a researcher’s cryptanalysis and a vendor’s reliance on certification and its own threat assessment; CERT/CC published both.
  • Pacom 1000 GMS (2015). ICS-CERT advisory ICSA-15-337-03, first posted to the US-CERT portal on 3 December 2015, reported cryptographic implementation flaws in “network-enabled security panels that control, monitor, and maintain security for a remote site and control all alarm and door functions”; the flaw “can be used by a perpetrator to take control over the communication between the controller and base station”. At the time of the advisory Pacom had not patched the affected 1000 CCU and RTU units of its GMS system, but had released fixed firmware for its newer EMCS system.35
  • Wireless sensors (DEF CON 22, 2014). Logan Lamb of Oak Ridge National Laboratory examined systems from ADT, Honeywell and Vivint and reported that an attacker could “suppress alarms, create false alarms, and collect artifacts that facilitate tracking the movements of individuals”. On the Honeywell system tested, the panel’s radio-jam detection could be evaded, and he observed that “the alarm devices implicitly trust the sensor communications”.36
  • Johnson Controls PowerG, IQPanel and IQHub (2025). CISA advisory ICSA-25-350-02 of 16 December 2025 (updated 5 March 2026) reported that in the PowerG wireless sensor protocol an attacker could “capture the network key and read or write encrypted packets”, that “nonce reuse” allowed replay, and that a weak pseudo-random number generator could let an attacker “read or inject encrypted PowerG packets”. IQ Panel 2, 2+ and IQ Hub were affected in all versions; Johnson Controls recommended upgrading or replacing end-of-life units.37
  • Honeywell MB-Secure (2025). Honeywell’s security notice SN 2025-05-01-01 disclosed CVE-2025-2605, an operating-system command injection in MB-Secure and MB-Secure PRO alarm control panels that could allow an attacker “to execute malicious commands with elevated permissions”, reported by SEC Consult and fixed in later firmware. Honeywell scores it 9.9 under CVSS 3.1.38 The US National Vulnerability Database published the CVE on 2 May 2025 and gives its own CVSS 3.1 score of 8.8.39
  • Cellular communicators (2026). A paper at MobiSys 2026 by Min-Yue Chen and colleagues, “Insecurity of Lost/Stolen Phone Reporting Services”, published on 20 June 2026, examined weaknesses in carriers’ lost-and-stolen device reporting.40 Michigan State University’s account describes a proof-of-concept called “Home Security System Freezing” that “could prevent cellular-connected home security systems from communicating with homeowners and monitoring centers”, and says the researchers “tested representative home security gateways and found that two major U.S. home security providers, together accounting for more than 41% of the U.S. market, use cellular IoT modem chipsets that are vulnerable”.31 The market share is the university’s report of the researchers’ estimate.

These sources do not identify any UL 2050 installation as affected, and they do not compare certificated and uncertificated installations. They show that communicators, panels, wireless sensors and monitoring-related software have shipped with flaws whose documented effects include forged or suppressed alarm messages and command execution on a panel. Line supervision is designed to detect tampering with or malfunction of the line; a well-formed forged message on a working path is a different kind of failure.14

What the standards say about the station’s own security

UL has treated the automation system as a computer for over a decade; UL’s Pete Tallman reported in January 2014 that the UL 1981 revision added “a common section ... for automation system access security”.41 A UL certification requirement decision on edition 5 of UL 2050 (5 November 2010), published with NISPPAC papers in a 2016 copyright version, observed that “the current edition of UL 2050 is silent on the redundancy and maintain operation if a single point were to fail.” For that edition it required high-availability computers with duplicated power supplies and network connections, a failover exercised “at least once in every consecutive thirty day period”, restoration within 24 hours, daily backups, encrypted WAN communications and remote-access controls.19 Whether edition 6 (7 April 2025) keeps these provisions is not shown in UL’s public catalogue entry.24

The SCIF specification goes further. A networked IDS host must sit in a “Physically Protected Space”, a locked room to which only SCI-cleared personnel have access, with others escorted, protected by an alarm and access control “unless manned 24 hours”; components must be isolated by measures that “may include, but are not limited to” firewalls and VPNs; if any component is remotely programmable, “continuous network monitoring is required”; administrators must change default PINs; and “All Host systems and PCUs shall be patched and maintained to implement current firmware and security updates.”9 NFPA 731, the Standard for the Installation of Premises Security Systems, took up the subject in committee draft language in its 2021 First Revision report: a purpose statement that the standard “addresses the integrity and reliability of cyber intrusion protection for equipment or systems network connected to the Internet of Things (IoT)” and a standalone cybersecurity section “because of the growing concern and importance of cyber related issues”.42

The public summaries of UL 827 and UL 1981 do not state their cybersecurity clauses. What the public record supports is that the automation system and remote access are within the scope of UL 1981 and the UL 2050 decision, and that a certificate does not tell the subscriber how a given station configures them.

Evidence on alarms and response

Most police alarm calls were false

The US Department of Justice’s Problem-Oriented Guide False Burglar Alarms (second edition, 2007) by Rana Sampson is the standard public summary of police alarm data, and its figures are old: the guide was published in 2007, and the local examples used here date from 1999 to 2006. It reports that “the vast majority of alarm calls—between 94 and 98 percent (higher in some jurisdictions)—are false”, that false alarms account for “between 10 and 25 percent of all calls to police”, and gives examples such as Dallas, where only 2.8 percent of 62,000 alarm calls in 2004 were valid.43 It names three main causes: user errors such as incorrect keypad codes, open doors or windows, pets and poor employee training; “faulty or inappropriately selected equipment”; and “poor installation”. Commercial users’ false-alarm rates “may be as much as three times higher” than residential, because more people share responsibility for arming and disarming and the systems tend to be more complex.43 These are police-dispatch figures; they say nothing directly about how often a monitoring centre’s own assessment filters alarms out before calling police.

The Los Angeles Police Department’s undated account of its alarm programme gives similar proportions without dating its baseline: it responds to “more than 100,000 privately installed burglar alarm calls” a year, “of which 97% are determined to be false alarms”. Under a 2004 policy each location gets “two false alarm activations within a rolling year”, after which “verification will be required in order to dispatch the call to a patrol unit”; unverified calls are broadcast so that patrol units can respond voluntarily if available. The page credits the policy with a 25 percent fall in alarm calls handled by patrol units.44

Verified response

Some police agencies go further. Sampson describes verified response, in which “alarm monitoring companies must verify the legitimacy of alarms (except holdup, duress, and panic alarms) before calling the police”, typically by on-scene or video verification, and reports that cities adopting it “have found enormous decreases in the number of alarm calls, typically around 90 percent”. Requiring the monitoring company to try two or more numbers before calling police (“enhanced call verification”) brought “modest reductions (around 25 to 40 percent) in the number of false alarm calls to police” in the jurisdictions that adopted it; those are observed results, not a prediction for another jurisdiction. Audio verification fared badly: in 2006 the Fremont, California, police found a 96 percent false rate on a year of audio alarms.43

The trade-off is real on both sides. For police, verification sharply cuts call load; the guide reports that insurers in verified-response cities “continue to provide discounts to alarm owners”.43 Against it, the guide records arguments “that the public expects a police response and police are better trained than private security to respond to such situations”, and notes that jurisdictions with few, scattered alarm customers may struggle to find a private responder with “satisfactory and cost-effective response times”, though police there likely respond slowly too; the alarm industry “has defeated verified response proposals in many other cities”.43 For an alarm owner, where police will not respond to an unverified intrusion alarm, the police segment of the timeline begins only after a guard, a camera operator or another source confirms the intrusion, and an intrusion that is never verified may get no police response at all. For cleared contractors whose primary response is the police, 117.15 separately requires written assurance from the police department about response in the required time.14

Faster dispatch, same physics

APCO and The Monitoring Association (TMA, formerly the Central Station Alarm Association) have addressed one handoff in the timeline: the telephone call from the monitoring centre to the emergency communications centre. Their Automated Secure Alarm Protocol (ASAP), now APCO/TMA 2.101.3-2021, is a data exchange “streamlining alarm notifications between alarm monitoring companies and public safety Emergency Communications Centers since 2009”; the 2021 revision emphasised address verification and added ways “to indicate that an alarm has been verified positively”.45 An SDM Magazine article by TMA’s Celia Besore in January 2023 described alarm data delivered “directly into the CAD system at the PSAP/ECC in seconds” and reported that “more than 85 percent of all alarm accounts are ASAP enabled” as of 1 December 2022, an industry figure given without its base or its coverage of any particular ECC.46 Faster, more accurate handoff shortens that one segment. It does not shorten the drive, and it does not change whether police will come to an unverified alarm.

A worked timeline

The figures in this example are hypothetical and chosen only to show the method. Top Secret is held in a GSA-approved container in an alarmed room, and the CSA has approved IDS supplemental protection with 15-minute arrival. The adversary’s objective is to remove the material from the building; the responders can intervene only once they have deployed at the room or its exit in enough strength to stop the adversary. The facility security officer, not the alarm company or the station, owns the integrated test, because only the facility sees the whole chain.

SegmentHypothetical time
Adversary, after the room’s door switch first detects: reach the container1 minute
Adversary: open the container (a validated estimate for the assumed threat and tools, not a test rating)8 minutes
Adversary: leave the room1 minute
Adversary task time remaining after first detection10 minutes
Defender: sensor to panel to station, annunciated0.5 minute
Defender: operator assesses, activates the response and dispatches2 minutes
Defender: responders travel to the facility and arrive12 minutes
Defender: responders reach the room and deploy1 minute
Time from first detection to effective deployment15.5 minutes

This single response passes the 2001.43 timing criterion, because arrival comes 14 minutes after annunciation; whether the installation complies also depends on the equipment and approval conditions, and for a cleared contractor the response record is judged against the 117.15 standard of 80 percent within the limit.2614 On timely detection it fails by five and a half minutes, because the responders deploy after the adversary has left.2 Moving first detection to an alarmed outer door five minutes’ travel from the room would add five minutes to the adversary’s remaining time, but only if the outer sensor covers every path and performs as measured; that still leaves a half-minute shortfall. If video then cut assessment and activation from two minutes to one, as measured in tests, deployment would come at 14.5 minutes against 15, a half-minute margin.132 The acceptance threshold should be stated against the measured distribution of times to effective deployment, not the mean. The 117.15 records of receipt, dispatch and arrival are a starting point once receipt times have been correlated with annunciation, and intervention has to be measured separately in exercises.142

What to do differently when specifying or auditing an alarm system

  1. Write the timeline down and measure it. List the adversary’s task times after first detection, using separately validated elapsed-time estimates for the assumed threat rather than container or lock test ratings, and the response segments from Sandia’s definition: detection, alarm communication, assessment, dispatch and deployment.229 Use the 117.15 records of receipt, dispatch and arrival, after correlating receipt with annunciation, as one input to the response distribution, measure deployment and intervention separately, and look at the slow tail as well as the average.142
  2. Treat the certificate as an inventory, then check what it omits. Read the alarm system description form and certificate for extent of protection, line security type, encryption standard and any approved response-time extension; 117.15 requires a CSA-approved Top Secret extension to be noted on the certificate, and the SCIF specification requires the encryption standard.149 For mercantile service, ask what response the service agreement promises, because UL leaves that to the contract.20
  3. Move first detection outward and make sure it can be assessed. Delay before detection earns no credit toward interruption, and delay counts only once an alarm has been assessed and the response activated.12 Put detection at the outer layer where you can, and pair exterior sensors with video assessment, which UFC 4-021-02 calls “especially important” outdoors because of nuisance rates.3
  4. Specify the sensor configuration. Require UL 634 Level 2 switches with monitored tamper circuits on doors that matter, “or” logic on dual-technology sensors in the high-security areas where UFC requires it, with each technology alarming independently as the SCIF specification requires, and a walk test of the four-step coverage goal and the SCIF three-of-four acceptance test.39
  5. Budget nuisance alarms and enforce the budget. Adopt UFC’s NAR and FAR limits, with their averaging periods, or the SCIF limit of one false alarm per partition per 30 days, state which definition you use, track alarms by zone and investigate exceedances.39 The DOJ guide’s main causes of police-reported false alarms, user error, equipment and installation, are a starting checklist.43
  6. Settle police response before relying on it. Check whether the jurisdiction uses verified response or limits dispatch after false alarms, and, if police are the primary response, obtain both the CSA authorisation on the alarm system description form and the written police assurance that 117.15 requires.444314
  7. Test the path’s resilience. Ask whether every premises-to-station path is encrypted and authenticated; the older DC-09 text made encryption support optional for premises equipment.32 In authorised acceptance tests, include loss of the IP and cellular paths and radio interference with wireless sensors, and document the expected result for each: a loss of service should produce a trouble signal and the documented fallback, while integrity failures such as forged messages may not be visible to supervision and need cryptographic protection instead.3637914
  8. Treat panels, communicators and the station as patched IT. Track vendor advisories for every panel, communicator and wireless sensor type in the system and change default PINs.37389 Ask the monitoring station for its documented automation-system redundancy, patching and remote-access controls under the edition of UL 2050 or UL 827 it is listed to.1924
  9. Plan for the alarm system being down. Write the occupation or guard procedure for a failed IDS into the emergency plan, as the SCIF specification requires, and rehearse it; where line security is unavailable, the two-path design under 117.15 needs CSA authorisation in advance.914

Conclusion

An alarm stops an intruder only as part of a timeline. UL alarm service certificates, the UL 827 station listing and UL 2050 certification put audited floors under the components, installation and monitoring, and 32 CFR 2001.43 and, for cleared contractors, 117.15 write arrival deadlines for classified storage. None of them certifies that the response arrives before the adversary finishes, and a response can pass the 15-minute timing criterion while losing that race, as the worked timeline shows. The decision that follows is about where to put detection: delay earns credit only after an alarm is detected and assessed and the response is activated, so moving first detection outward and shortening assessment buy more time than a better certificate. False-alarm history, police verification policies and documented flaws in communicators, wireless sensors and panels show where the remaining margin is lost, and each is something the specifier can measure and test.

Footnotes

  1. Mary Lynn Garcia, “Risk Management”, SAND2004-6286P, Sandia National Laboratories, 2004. https://www.osti.gov/servlets/purl/1728532 (opens in a new tab) ↩1 ↩2 ↩3 ↩4
  2. “16. Evaluation of Physical Protection Systems” and following chapters, SAND2007-5502P, Sandia National Laboratories, The Twentieth International Training Course, 2007. https://www.osti.gov/servlets/purl/1721450 (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12
  3. UFC 4-021-02, Electronic Security Systems, US Department of Defense (Unified Facilities Criteria), 28 July 2025. https://www.wbdg.org/FFC/DOD/UFC/ufc_4_021_02_2025.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24 ↩25 ↩26 ↩27 ↩28 ↩29 ↩30 ↩31 ↩32 ↩33 ↩34 ↩35 ↩36
  4. NAVFAC Design Manual DM-13.02, Commercial Intrusion Detection Systems, September 1986, section 4.1 “Point Sensors - Interior” (Integrated Publishing reproduction). https://navalfacilities.tpub.com/dm13_02/dm13_020049.htm (opens in a new tab) ↩1 ↩2
  5. NAVFAC Design Manual DM-13.02, Commercial Intrusion Detection Systems, September 1986, section “Balanced Magnetic Switches” (Integrated Publishing reproduction). https://navalfacilities.tpub.com/dm13_02/dm13_020051.htm (opens in a new tab) ↩1 ↩2 ↩3 ↩4
  6. UFC 4-021-02NF, Security Engineering: Electronic Security Systems, US Department of Defense, 2006 (with Change 1). https://www.wbdg.org/FFC/DOD/UFC/ARCHIVES/ufc_4_021_02nf_2006_c1.pdf (opens in a new tab) ↩
  7. UL 634, Connectors and Switches for Use with Burglar-Alarm Systems, edition 9 (12 October 2007, last revised 24 September 2025), scope, UL Standards & Engagement. https://www.shopulstandards.com/ProductDetail.aspx?productId=UL634 (opens in a new tab) ↩1 ↩2
  8. “SUN - UL 634, Connectors and Switches for Use with Burglar-Alarm Systems”, Intertek Standards Update Notice, revision of 27 March 2015, effective 27 March 2016. https://www.intertek.com/standards-updates/ul-634-connectors-switches-for-burglar-alarm-systems-use/ (opens in a new tab) ↩1 ↩2
  9. Technical Specifications for Construction and Management of Sensitive Compartmented Information Facilities, Version 1.5.1 (IC Tech Spec for ICD/ICS 705), National Counterintelligence and Security Center, 26 July 2021. https://archive.dni.gov/files/NCSC/documents/Regulations/IC_Technical_Specifications_for_Construction_and_Management_of_Sensitive_Compartmented_Information_Facilities_v151_PDF.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18
  10. “Intrusion Detection”, US Nuclear Regulatory Commission, page last reviewed 11 March 2020. https://www.nrc.gov/security/domestic/phys-protect/intrusion (opens in a new tab) ↩1 ↩2
  11. NAVFAC Design Manual DM-13.02, Commercial Intrusion Detection Systems, September 1986, section 4.2.3 “Microwave Sensors”, limitations (Integrated Publishing reproduction). https://navalfacilities.tpub.com/dm13_02/dm13_020066.htm (opens in a new tab) ↩1 ↩2
  12. UL 639, Intrusion-Detection Units, edition 8 (31 August 2007, last revised 18 June 2024), scope, UL Standards & Engagement. https://www.shopulstandards.com/ProductDetail.aspx?productId=UL639 (opens in a new tab) ↩1 ↩2
  13. NAVFAC Design Manual DM-13.02, Commercial Intrusion Detection Systems, September 1986, section 4.1.2.1 “Capacitance Proximity Sensors” (Integrated Publishing reproduction). https://navalfacilities.tpub.com/dm13_02/dm13_020055.htm (opens in a new tab) ↩1 ↩2 ↩3
  14. 32 CFR 117.15, Safeguarding classified information (NISPOM), eCFR point-in-time text as of 1 November 2026. https://www.ecfr.gov/api/versioner/v1/full/2026-11-01/title-32.xml?part=117&section=117.15 (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24 ↩25
  15. UL 1610, Central-Station Burglar-Alarm Units, edition 4 (5 July 2016, last revised 21 April 2021, now superseded), scope, UL Standards & Engagement. https://www.shopulstandards.com/ProductDetail.aspx?productId=UL1610 (opens in a new tab) ↩
  16. UL 1076, Proprietary Burglar Alarm Units and Systems, edition 6 (6 April 2018, last revised 16 February 2021, now superseded), scope, UL Standards & Engagement. https://www.shopulstandards.com/ProductDetail.aspx?productId=UL1076 (opens in a new tab) ↩
  17. UL 2610, Commercial Premises Security Alarm Units and Systems, edition 2 (7 April 2021, reaffirmed 17 December 2025), scope and list of superseded standards, UL Standards & Engagement. https://www.shopulstandards.com/ProductDetail.aspx?productId=UL2610 (opens in a new tab) ↩1 ↩2
  18. “Cryptographic Module Validation Program FAQs”, NIST Computer Security Resource Center, accessed 27 November 2026. https://csrc.nist.gov/projects/cryptographic-module-validation-program/faqs (opens in a new tab) ↩
  19. Underwriters Laboratories, Certification Requirement Decision on UL 2050 (edition 5, 5 November 2010), “Automation Systems”, 2016, published by the National Archives with NISPPAC papers. https://www.archives.gov/files/isoo/oversight-groups/nisppac/ul-2050-automation-system-proposals.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4
  20. “Security Alarm Service Certification”, UL Solutions, accessed 27 November 2026. https://www.ul.com/services/security-alarm-service-certification (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10
  21. UL 681, Installation and Classification of Burglar and Holdup Alarm Systems, edition 15 (16 January 2014, last revised 25 September 2025), scope, UL Standards & Engagement. https://www.shopulstandards.com/ProductDetail.aspx?productId=UL681_15_S_20140116 (opens in a new tab) ↩1 ↩2 ↩3
  22. UL 827, Central-Station Alarm Services, edition 9 (8 November 2022, last revised 24 August 2026), scope and summary of topics, UL Standards & Engagement. https://www.shopulstandards.com/ProductDetail.aspx?productId=UL827 (opens in a new tab) ↩1 ↩2 ↩3
  23. “National Industrial Security System Certification”, UL Solutions, accessed 27 November 2026. https://www.ul.com/services/national-industrial-security-system-certification (opens in a new tab) ↩1 ↩2 ↩3
  24. UL 2050, National Industrial Security Systems, edition 6 (7 April 2025), UL Standards & Engagement. https://www.shopulstandards.com/ProductDetail.aspx?productId=UL2050 (opens in a new tab) ↩1 ↩2 ↩3
  25. UL 1981, Central-Station Automation Systems, edition 3 (29 October 2014, last revised 29 March 2023), scope, UL Standards & Engagement. https://www.shopulstandards.com/ProductDetail.aspx?productId=UL1981 (opens in a new tab) ↩1 ↩2
  26. 32 CFR 2001.43, Storage (ISOO classified national security information directive), eCFR point-in-time text as of 1 November 2026. https://www.ecfr.gov/api/versioner/v1/full/2026-11-01/title-32.xml?part=2001&section=2001.43 (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5
  27. 32 CFR 2001.92, Definitions, paragraphs (s) and (t), eCFR point-in-time text as of 1 November 2026. https://www.ecfr.gov/api/versioner/v1/full/2026-11-01/title-32.xml?part=2001&section=2001.92 (opens in a new tab) ↩
  28. “Types of security containers”, General Services Administration, last updated 12 August 2026. https://www.gsa.gov/buy-through-us/purchasing-programs/requisition-programs/gsa-global-supply/national-stock-numbers/security-containers/types-of-security-containers (opens in a new tab) ↩
  29. Federal Specification AA-F-358K, Filing Cabinet, Legal and Letter Size, Uninsulated, Security, General Services Administration, 16 February 2023 (archived DoD Lock Program copy). https://web.archive.org/web/20250531001322id_/https://exwc.navfac.navy.mil/Portals/88/Documents/EXWC/DoD_Locks/PDFs/AA-F-358K.pdf (opens in a new tab) ↩1 ↩2 ↩3
  30. “DC-09-2026, SIA DCS: Internet Protocol Event Reporting”, Security Industry Association standards page, 2026. https://www.securityindustry.org/industry-standards/dc-09-2026/ (opens in a new tab) ↩1 ↩2 ↩3
  31. “Security flaws could block devices from cellular networks”, MSUToday, Michigan State University, 9 September 2026. https://msutoday.msu.edu/news/2026/09/security-flaws-could-block-devices-from-network (opens in a new tab) ↩1 ↩2
  32. SIA DC-09, Internet Protocol Event Reporting, Security Industry Association (text marked © 2007, 2013, 2017, 2020), sections 1 and 5.4 and Annex B, as reproduced by ReadKong. https://www.readkong.com/page/sia-digital-communication-standard-internet-protocol-8198159 (opens in a new tab) ↩1 ↩2
  33. “Security Industry Association Releases 2026 Revision to DC-09 Standard”, Security Industry Association, 3 March 2026. https://www.securityindustry.org/2026/03/03/security-industry-association-releases-2026-revision-to-dc-09-standard/ (opens in a new tab) ↩1 ↩2
  34. “CSL DualCom GPRS CS2300-R alarm signalling boards contain multiple vulnerabilities”, Vulnerability Note VU#428280, CERT Coordination Center, 23 November 2015. https://kb.cert.org/vuls/id/428280 (opens in a new tab) ↩
  35. “Pacom 1000 CCU GMS System Cryptographic Implementation Vulnerabilities”, ICS Advisory ICSA-15-337-03, ICS-CERT/CISA, first posted 3 December 2015, last revised 27 August 2018. https://www.cisa.gov/news-events/ics-advisories/icsa-15-337-03 (opens in a new tab) ↩
  36. Logan Lamb, “Home Insecurity: No Alarms, False Alarms, and SIGINT”, white paper, DEF CON 22, August 2014. https://media.defcon.org/DEF%20CON%2022/DEF%20CON%2022%20presentations/DEF%20CON%2022%20-%20Logan-Lamb-HOME-INSECURITY-NO-ALARMS-FALSE-ALARMS-AND-SIGINT-WP.pdf (opens in a new tab) ↩1 ↩2
  37. “Johnson Controls PowerG, IQPanel and IQHub (Update A)”, ICS Advisory ICSA-25-350-02, CISA, 16 December 2025, revised 5 March 2026. https://www.cisa.gov/news-events/ics-advisories/icsa-25-350-02 (opens in a new tab) ↩1 ↩2 ↩3
  38. “SN 2025-05-01-01: OS Command Injection in Honeywell MB-Secure (CVE-2025-2605)”, Honeywell security notice, May 2025. https://www.honeywell.com/content/dam/honeywellbt/en/documents/downloads/product-security/security-notification/hon-corp-os-command-injection-honeywell-mb-secure-2025-05-01-01.pdf (opens in a new tab) ↩1 ↩2
  39. “CVE-2025-2605”, National Vulnerability Database, NIST, published 2 May 2025. https://nvd.nist.gov/vuln/detail/CVE-2025-2605 (opens in a new tab) ↩
  40. Min-Yue Chen, Yiwen Hu, Yu-An Chen, Chi-Yu Li, Tian Xie and Guan-Hua Tu, “Insecurity of Lost/Stolen Phone Reporting Services: Vulnerabilities, Attacks, and Countermeasures”, Proceedings of MobiSys ‘26, ACM, pp. 520-533, 20 June 2026. https://doi.org/10.1145/3745756.3809220 (opens in a new tab) ↩
  41. Pete Tallman, “Central Station Monitoring Standards”, SDM Magazine, 23 January 2014. https://www.sdmmag.com/articles/89945-central-station-monitoring-standards (opens in a new tab) ↩
  42. NFPA 731 First Revision report (committee draft revisions, Technical Committee PMM-AAA), National Fire Protection Association, 2021. https://docinfofiles.nfpa.org/files/AboutTheCodes/731/731_F2022_PMM_AAA_FD_FRstatements.pdf (opens in a new tab) ↩
  43. Rana Sampson, False Burglar Alarms, 2nd edition, Problem-Oriented Guides for Police No. 5, Office of Community Oriented Policing Services, US Department of Justice, 2007 (Center for Problem-Oriented Policing printing, August 2011). https://popcenter.asu.edu/sites/default/files/problems/PDFs/false_alarms_2nded.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7
  44. “Alarm Section: History and Problems”, Los Angeles Police Department, undated, accessed 27 November 2026. https://www.lapdonline.org/police-commission/alarms-section-history-and-problems/ (opens in a new tab) ↩1 ↩2
  45. APCO/TMA 2.101.3-2021, Alarm Monitoring Company to Emergency Communications Center (ECC) Computer-Aided Dispatch (CAD) Automated Secure Alarm Protocol (ASAP), APCO International, 18 March 2021. https://www.apcointl.org/standards/alarm-monitoring-company-to-public-safety-answering-point-psap-computer-aided-dispatch-cad-automated-secure-alarm-protocol/ (opens in a new tab) ↩
  46. Celia Besore, “How TMA’s ASAP-to-PSAP Service Is Saving Time & Lives”, SDM Magazine, 17 January 2023. https://www.sdmmag.com/articles/101538-how-tmas-asap-to-psap-service-is-saving-time-and-lives (opens in a new tab) ↩